Local Listener / Configuring Local Commands host |
When Execute On Fail is enabled and the same failure occurs each time an action is run for a specific host, leaving this option unchecked suppresses multiple executions of the Execute On Fail command. If suppression of execution of the command for this failure continues after 24 hours, the suppressed Execute On Fail command will be executed every 24 hours and after a system restart if the failure occurs again. When the failure is resolved, the Execute On Fail command will be executed again. Users must account for this by including the %status% macro variable for the Execute On Fail command (see Using macro variables) and then checking for a success or failure.
Regarding non-CHECK commands: When Terminate On Fail is on, if a command fails, Email On Fail and Execute On Fail, if set, are processed, and then the action stops. When Terminate On Fail is off, if a command fails, Email On Fail and Execute On Fail, if set, are processed, and the action continues.
Regarding CHECK commands: Terminate On Fail is only honored if the ConditionsMet parameter is set and the result of the CHECK is classified as Error. The CHECK command is only available in the Cleo Harmony and Cleo VLTrader applications.